Multi Gas 측정기
- 모델명 : MCS 100E
- 측정항목 : HCI, SO₂, NOx, NH₃, CO, CO₂,O₂,H2O
- 측정원리 : 비분산적외선흡수법 (NDIR)
- SICK-MAIHAK社 Sampling방식의 대표적인 모델로 한국시장 내 소각로 현장에서 가장 많은 공급실적이 있는 모델
- NH3, HCI등의 수용성가스를 수분을 제거하지 않고 성상 그대로 측정하므로 정확하고 신뢰성있는 측정가능
- 수분 제거장치가 없으므로 구성이 간단
- 최대 8 항목측정 가능
- 각 항목의 2개의 측정범위 자동선택
- 자동 영점 기능/간섭 보정 기능/ 기압 보정(옵션)
제품소개 및 관련자료
+ 흐름도
+ 측정원리
제품사양
Measuring Principle | Infrared photometer, dual wavelength or gas filter correlation technique |
Spectral Range | 1 - 16㎛ |
Components Measured | |
MCS CD | SO₂, CO, NO, NO₂, N₂O, CO₂, O₂ |
MCS HW | NH₃, HCI, H₂O, SO₂, CO, NO, NO₂, CO₂, O₂ |
Number of Components | max. 8+ O₂ |
Response Time(T90) | < 140 s |
Measurement Ranges | For each component 2 measuring ranges, with automatic range selection, freely programmable |
Limits | Two limits freely programmable for each component as "normally closed" or "normally open" relay |
Detection Limits | < %2 of the particular measurement range |
Barometrical Correction | 0.7 - 1.2 bar ambient pressure variations (option) |
Interference Compensation | Taking account of up to a maximum of 4 inter fering variables, external variables also possible |
Linearization | Automatic after input of the calibration values |
Sensitivity Control | Span gas, internal calibration cells as an option |
Measurement Point Selection | Integrated control for 12 measurement points |
Calibration Cells | max.3 each |
Interfaces | 2optical |
Keyboard | numeric membrane keyboard with arrow and function keys, external keyboard attachable |
Operation | 2 operating levels for user and specialist (password-protected) Time programs freely programmble |
Computer | 386 SX or higher |
Memory | 2MB(up to 32MB, as an option) silicon disc |
cell | |
Optical Path Length | 3m or 6m pre-adjusted |
Temperature | 100 iC or 185 iC, max.200 iC |
Volume | 2L |
Gas Flow | 200 - 600 L/h (depends on application) |
Filter Porosity | 10㎛ |
Housing | |
Dimensions | 665mm x 440mm x 360mm (H x W x D) |
Material | Sheet steel |
Weight | approx. 70Kg |
Color | RAL 7032(grey) |
Degree of Protection | IP 53 |
Ambient Temperature | + 5 iC to + 335 iC |
Ambient Humidity | up to 80% (non-condensing) |
Power Supply | 115/230V + 10% /-15 %/60/50Hz |
Power Consumption | 850 VA |
Compliances | IEC 1010-1/A1+A2:1995 |
EMV | EN 50 081-2:93 and 50 082-2:95 |